Proline Promag 50W, 53W
4 Endress+Hauser
PROFIBUS PA interface:
Transmission technology (Physical Layer): IEC 61158-2 (MBP), galvanically isolated
Profile version 3.0
Current consumption: 11 mA
Permissible supply voltage: 9...32 V
Bus connection with integrated reverse polarity protection
Error current FDE (Fault Disconnection Electronic): 0 mA
Function blocks: 1 x analog input, 1 x totalizer
Output data: volume flow, totalizer
Input data: positive zero return (ON/OFF), control totalizer, value for local display
Cyclic data transmission compatible with previous model “Promag 33”
Bus address adjustable via miniature switches or local display (optional) at the measuring device
Promag 53
Current output:
active/passive selectable, galvanically isolated, time constant selectable (0.01...100 s),
full scale value selectable, temperature coefficient: typically 0.005% o.r./°C (o.r. = of reading),
resolution: 0.5 µA
active: 0/4…20 mA, R
L
< 700 (HART: R
L
250 )
passive: 4…20 mA, operating voltage V
S
18...30 V DC, R
i
150
Pulse/frequency output:
active/passive selectable, galvanically isolated (Ex i version: only passive)
active: 24 V DC, 25 mA (max. 250 mA during 20 ms), R
L
> 100
passive: open collector, 30 V DC, 250 mA
Frequency output: full scale frequency 2...10000 Hz (f
max
= 12500 Hz), EEx-ia: 2...5000 Hz;
on/off ratio 1:1; pulse width max. 10 s.
Pulse output: pulse value and pulse polarity adjustable, pulse width configurable
(0.05...2000 ms)
PROFIBUS DP interface:
Transmission technology (Physical Layer): RS485 in accordance with ANSI/TIA/EIA-485-A:
1998, galvanically isolated
Profile version 3.0
Data transmission rate: 9.6 kBaud...12 MBaud
Automatic data transmission rate recognition
Function blocks: 2 x analog input, 3 x totalizer
Output data: volume flow, calculated mass flow, totalizer 1...3
Input data: positive zero return (ON/OFF), totalizer control, value for local display
Cyclic data transmission compatible with previous model “Promag 33”
Bus address adjustable via miniature switches or local display (optional) at the measuring device
Available output combination Page 7 ff.
PROFIBUS PA interface:
Transmission technology (Physical Layer): IEC 61158-2 (MBP), galvanically isolated
Profile version 3.0
Current consumption: 11 mA
Permissible supply voltage: 9...32 V
Bus connection with integrated reverse polarity protection
Error current FDE (Fault Disconnection Electronic): 0 mA
Function blocks: 2 x analog input, 3 x totalizer
Output data: volume flow, calculated mass flow, totalizer 1...3
Input data: positive zero return (ON/OFF), totalizer control, value for local display
Cyclic data transmission compatible with previous model “Promag 33”
Bus address adjustable via miniature switches or local display (optional) at the measuring device